Node Configuration

Each node has a section in the config file with the same name as the node. This name must correspond to the name of the node in the .drawio XML file. This looks like:

[name]
type=xxxx

The required type keyword is used to specify the type of node. The possible values are:

Each of these has specific configuration options

pwrOnOffNode

The power-on/off node shows the status of a power switched device.

key type required default Description
pwrKey string Y The INDI key (device.propery) of the power switch

stdMotionNode

The standard motion node shows the status of an standard motion stage, which includes focus stages, filter wheels, linear actuators, etc.

key type required default Description
device string N <node name> The INDI device name, defaults to the node name specified in the drawio file
presetPrefix string N preset The prefix for preset, usually preset or filter
presetDir string N output Allowed values are input or output. Specifies which put (in or out) corresponds to the preset.
presetPutName vector<string> N out Names for the put which correspond to the preset. If more than one, the preset controls which one is on.
alwaysOn vector<string> N Names of outputs which are always on if any input is.
noAutoOn vector<string> N Names of outputs which are not automatically turned on by an internal link to an input
trackerKey string N If set, this is the INDI key of the tracking property
trackerElement string N If set, this is the element of the tracking property